CALIBRATION TEST BENCHES & SYSTEMS
- Primary & Secondary Standards

Comprehensive Range covering Manual / Semi-Automatic / Automatic Calibration of Pressure / Temperature / Electrical parameters
Powerful tools for Total Quality Management & ISO Conformance.
Modular design with space for future add-ons, compact & sleek Work Station furniture - Table / Under-bench Cabinet / Bench-top / Side Trolley etc.
Offers ultimate flexibility thro' custom configuration / preferences enabling incorporation of world's best furniture, utility modules,
   calibration standards & test and measuring instruments.
Accuracy of Calibration Modules traceable to International Standards.


- brief specifications -

Primary Standard Pressure Calibration Workstation
System 1000, 1100 & 1200

 

 

 

 

 

 

Detailed Datasheet
System 1100

 

 

Detailed Datasheet
System 1200

- the ultimate Primary Standard




 includes
 'Betz' Micromanometers (±300 & ±1000 mmWC, Accuracy/Resolution
    - Maximum 0.03% FSD/0.002% FSD) & Precision Manometers Ranges upto
    1350 mbar, Accuracy/Resolution 0.02%/0.002% FSD). (Cost effective lower
    accuracy ±0.1%/0.2% FS Manometers also available).
Pneumatic & Hydraulic Dead Weight Testers (for Ranges/Accuracies refer to
    Dead Weight Testers Section above). (Higher Accuracy 200/150/80 PPM
    Dead Weight Testers also available).
Cascading Digital/Analog, Pressure/Vacuum Indicator/Gauges
    (Ranges Vacuum upto 700 bar, Accuracy upto 0.025% FS).
Precision Multifunction Calibrator (Temperature & Electrical Signal Calibration
    - Accuracy 0.01% Reading)
Continuity Tester
Precision Digital Multimeter, 6½ Digit
Air Set & Pressure/Vacuum generation & Control Panel
Stabilized DC/Variable AC Power Supply.

Option : Can be integrated with the powerful Calman* Software.

Modular Calibration System
System 2000
Detailed Datasheet
- the versatile Secondary Standard Bench / Tabletop - Trolley mounted
 includes 
 Upto 2 Temperature Calibrators (Digital/Microprocessor based) - rack mounted
    with integral / separate heating/cooling towers - Ranges upto 650°C.
Upto 2 Pressure Calibrators (Digital/Microprocessor based) - Pneumatic/Hydraulic - rack
    mounted with integral / separate Hand Pumps - Ranges upto 700 bar.
High Accuracy Multifunction Calibrator & Digital Multimeter (optional)
Standard AC/DC, Fixed/Variable Power Supplies
 


Pressure Calibration Workstation
System 3000, 3600

 

Detailed Datasheet
System 3000

 

 

Detailed Datasheet
System 3600

- the versatile Secondary Pressure Standard


 includes
  2 of 3 Digital/Microprocessor based Pressure Calibrators (Accuracy upto 0.025% FS)
    - Ranges : Pneumatic (upto 40 bar) and Hydraulic (upto 700 bar) with matching
    integral/external Hand Pumps with vernier adjustment
Digital Pressure Controller (Vacuum upto 10/60 bar- Pneumatic)/Precision Multifunction Calibrator,
    (Temperature & Electrical Signal Calibration 0.01% Reading Accuracy)
Programmable DC Power Supply & Variable/Stabilised AC Power Supply
6½ Digit Digital Multimeter, Fixed/Variable Power Supplies
Air Set Module

Optional : Calman* Calibratin Management Software.


Modular Calibration System
System 5000
Detailed Datasheet
- for Electrical / Electronic Instruments - the ultimate Electrical Workstation
- Designed to meet the Testing / Calibration requirements of Power Sector / Petrochemicals /
  Refineries etc.


 includes 
  3 & 1 Phase Multifunction Precision Power Meter (1000 V/30 A, Accuracy 0.2%)
    (& matching AC/DC V/A supply source).
High Accuracy Multi-function Calibrator
   (Temperature & Electrical Signal Calibration - 0.01% / 0.02% Reading Accuracy)
Function Generator (upto 20 MHz)
Precision Digital Multimeter, 6½ Digit
Precision Decade Resistance Box (0.01O upto 1 MO)
Fixed DC Power Supplies ±5 to ±48 V & or Adjustable/Programmable DC Power Supply
    (0 to 30/60 V)
Stabilized/Variable AC Power Supply
Air Supply Module
Soldering/De-Soldering Station
Continuity Tester & Socket Panel
 



Temperature Calibration Bench
System 6000
Detailed Datasheet
- the quick check Temperature Calibration Station
-
- suitable for fast checking/calibration of TC/RTD Inserts/Probes
 includes 
 2 or 3 Microprocessor based Dry Block Temperature Calibrators mounted ready for use.
    - Range -40°C (from Ambient) to 1200°C
Semi / Working Standard Thermocouple / RTD
Precision Multifunction Calibrator
    (Accuracy 0.01% Reading - Temperature & Electrical Signal Calibration)
Precision 6½ Digit Digital Multimeter
Programmable DC Power Supply
Air Supply Module
 



Temperature Calibration Bench
System 7000
Detailed Datasheet
- the HEAVY DUTY CALIBRATION Workhorse
-
Suitable for simultaneous checking / Calibration of multiple, bulk & odd size Sensors
 includes 
  Cryostatic Bath (-40 to 100°C) (Working Chamber 150x150 X Depth 250 mm)
Fluidized Bath (50 to 600°C) (Working Chamber Dia 165 mm X Depth 250 mm)
Precision Standard Reference Glass Thermometers Set (-50 upto 600°C)
Precision Multifunction Calibrator
   (Accuracy 0.01% Reading - Temperature & Electrical Signal Calibration)
Precision 6½ digit Digital Multimeter
Programmable DC Power Supply
Air Supply Module
Thermally insulated Bench-top
 

Optional : System 6000 & 7000 above can be upgraded as Computer Aided Calibration System for Automatic/Semi-Automatic Calibration - using Nagman's Caltemp/Calman Software. 6 Point Scanner Hardware/Software Module.


Computer Aided Calibration Workstation
System 9000 / 9600

 

Detailed Datasheet
System 9000

 

 

 

Detailed Datasheet
System 9600

- for Multi-parameter (Temperature, Pressure & Electrical / Electronic, Signal) / Multi-function
-
the ultimate (automatic) Calibration System


 includes
  2 or 3 mP based High Accuracy Dry Block Temperature Calibrators, Trolley mounted ready for use
   (-40°C to 1200°C)
2 or 3 mP based Pressure Calibrator Modules (Accuracy upto 0.025% FS) / Pneumatic/Hydraulic -
   Ranges Vacuum to 700 bar - rack mounted with integral/separate Hand Pumps with Verniers
Digital Pressure Controller (Vacuum upto 60 bar - Pneumatic)
Very High Precision Multifunction Calibrator (Temperature/Electrical Signal Calibration
    0.01% Reading Accuracy)
Optional : 3 & 1 Phase Multifunction Power Meter & matching AC/DC V/A Supply Sources.
Precision 6½ Digit Digital Multimeter
Programmable DC Power Supply
Variable AC Power Supply
Air Supply Module
Space for Computer System (CPU, Monitor, Keyboard, Mouse & Printer)


The entire System is integrated with the powerful Calman* Software (of Nagman)
for Automatic / Semi-Automatic / Manual Calibration & generation of Certificates per ISO Standards.

6 Point Scanner Hardware/Software Modules - optional

System 9000 (Multical) offers lower end Nagman Temperature / Pressure Calibrator Modules & other utilities as above but without Computer Interface.


 
Detailed Specifications of Modules mounted in Systems 1100, 3600, 5000, 7000 & 9600
Click to view
Attractive Optional Features / Facilities for Systems 1100, 3600 & 5000
 
Photos of Test Benches supplied to our overseas customers




Home | News | Export | Search | Career | Sitemap | About Us | Principals | Bargains | Products | Projects | Contact Us
CEO's Message | Group Companies | Query Submission | Calibration Center | Customer Opinion