brief specifications - |
|
Dry
Blocks - Basic Models |
![]() | Sub-Zero Temperature Calibrator | R-40 | |
| Range -40°C from Ambient to 123°C, Accuracy ±0.5°C, Resolution 0.1°C, Stability ±0.05°C, Well Dia/Depth 19/100 mm - Single/Multi-hole Inserts |
![]() | Low
/ Medium Temperature Calibrators |
350E,
650E | |
| Fixed Dry Block - Multihole - Range 10/20°C above Ambient to 350°C / 650°C, Accuracy better than ±1°C/±1.5°C, Resolution 0.1/1°C, Stability ±0.2°C upto ±0.5°C, Dry Block OD/Depth 38 mm/120 mm |
![]() | Heavy
Duty Low/Medium Temperature Calibrators |
350H,
350H2, 650H, 650H2 | |
| With an array of Interchangeable Thermowells - Single & Multi-hole - Range 10/20°C above Ambient to 350°C/20°C above Ambient to 650°C, Accuracy ±1°C (350 H/H2), ±1.5°C (650 H/H2), Resolution 0.1/1°C, Stability ±0.3 upto ±0.6°C, Interchangeable Thermowells: OD 25 mm, Depth 120/200 mm |
![]() | Economy Calibrators | ETC
600 & 600-2 | |
| Cost
effective, with Interchangeable Thermowells - Single & Multi-hole. Range 20°C
above Ambient to 600°C, Accuracy ±0.1%/0.15% FS, Resolution 1°C,
Stability ± 0.5°C, Interchangeable Thermowells OD 25 mm, Depth 120/200
mm. Analog output |
![]() | High
Temperature Calibrator |
1200HN | |
| With
Interchangeable Single/Multi-hole Thermowells - Range 300 to 1200°C, Accuracy
±3°C, Stability ±0.5°C (upto 600°C) & ±1°C
(above 600°C), Multi-hole Inserts, OD/Depth 45/150 mm. Heating time (max.)
60 minutes. Digital Temperature Indicator for Measurement and Reference (Comparison)
Thermocouple are available - optional. |
![]() | Very
High Temperature Calibrator |
1500
HN | |
| Ceramic Dry Block with Single/Multi-hole Inserts, Semi-Portable. Range 500°C to 1500°C, Accuracy 0.5% of span, Stability ±2°C, Interchangeable Single (7, 11 & 15 mm) / Multi-hole Inserts, 250 mm Immersion. Heating time (max.) 120 minutes. Floor Model on castor wheels. |
|
Dry
Blocks - Advanced High Accuracy Models - Microprocessor based |
![]() | Sub-Zero Temperature Calibrator | MP40-R | |
| Range -40°C from Ambient to 123°C, Accuracy ±0.3°C, Resolution 0.1°C, Stability ±0.05°C, Well Dia/Depth 19/100 mm - Single/Multi-hole Inserts. |
![]() | Medium Temperature Calibrator | MP650 | |
| Range 50 to 650°C, Accuracy ±0.7°C, Resolution 0.1°C, Stability ±0.06°C, Well Dia/Depth 26/110 mm - Single/Multi-hole Inserts. |
![]() | 2-in-1 Hot Cold Temperature Calibrator |
MP40-R
& MP650 | |
| Range -40°C from Ambient to 650°C, other features / specifications per MP40R, MP650, Space Saver. |
![]() | Universal Temperature Calibrators |
MTC 350 & MTC 650 | |
| The ultimate field Temperature Calibrator - with Measurement capability for most Thermocouples, RTDs, mV/mA/Resistance etc., Range 50°C to 350°C / 650°C, Accuracy ±0.4°C/± 0.6°C, Resolution 0.1°C, Stability ±0.05°C, 4X16 LCD dual display, Well Dia/Depth 25/150 mm. Single/Multi-hole Inserts, RS-232 Computer Interface, Calibration Software as standard. |
|
Stirred
Baths |
![]() | Micro
Oil Bath |
MOB
250 | |
| Ideal for Calibration of Multi-hole/Multi-type/odd shaped Sensors. Portability of Dry Block & Precision of Oil Bath, Range 20°C above Ambient to 250°C, Accuracy 0.6°C, Resolution 0.1°C, Stability 0.1°C, Working Chamber Dia/Depth 100/120 mm. Compact Size & Portable. |
![]() | Fluidized Baths | FB-06L
& FB-06S | |
| Ideal for High Temperature Calibration of Multi-hole/Multi-type/odd shaped Sensors. Range 50 to 600°C, Accuracy ±1.5°C, Resolution 1°C, Stability ±0.5 to 1°C, Working Chamber 165/225 mm Dia x 250/400 mm Depth, Cooling Coil & Evacuation System - Standard; Equalizing Block, Probe Carrier/Basket - optional. Floor Model on Castor Wheels. |
![]() | Fluidized Bath - Miniature | FB-06
Min | |
| Miniature/Portable Model, ideal for field use. Range 50 to 500°C, Accuracy ±1°C, Stability ±0.5°C, Working Chamber Dia/Depth 100/200 mm. |
![]() | Cryostatic Bath | CR-04 | |
| Range -40 to 100°C, Resolution ±0.1°C, Accuracy ±0.7°C, Uniformity ±0.1°C, Working Chamber 150 x 150 mm, Immersion Depth 250 mm - Floor Model on Castor Wheels |
![]() | Hot Cold Bath | HC-09 | |
| 2-in-1 Bath, Fluidized & Cryostatic Bath - space saver - specifications/ features per FB 06-S/CR-04. |
|
Black
Body Calibration Systems |
![]() | Low Temperature Calibration System |
BBSL | |
| Range 20°C above Ambient to 350°C, Resolution 0.1°C, Accuracy <0.5% reading (Min. 1°C), Stability ±0.5°C, Aperture Ø 25 mm, Emissivity 0.98 |
![]() | Medium
Temperature Calibration System |
BBSM | |
| Range 20°C above Ambient to 600°C, Resolution 0.1/1°C, Accuracy <0.5% reading (Min 2°C), Stability ±0.5°C, Aperture Ø 25 mm, Emissivity 0.97 to 0.98 |
![]() | High
Temperature Calibration System |
BBSH | |
| Range 500 to 1200°C, Resolution 1°C, Accuracy <0.5% reading (Min. 3°C), Stability ±1.5°C, Aperture Ø 25 mm, Emissivity better than 0.97 |
![]() | Very High Temperature Calibration System |
BBS-VH | |
| The 'True' Black Body - Range 500 to 1300°C, Resolution 1°C, Accuracy <0.3% reading, Stability ±0.5°C, Aperture Ø 25 mm, Emissivity better than 0.99, Semi-Portable |

| Home | News | Export | Search | Career | Sitemap | About Us | Principals | Bargains | Products | Projects | Contact Us |
| CEO's Message | Group Companies | Query Submission | Calibration Center | Customer Opinion |